LK201 C200H PDF

Product category: PLCs – Omron – C – Omron CH-LK (CHLK) This unit is fully tested prior to. Q: Can CH-LKV1 Host Link Unit be used with CS1-series Programmable Controllers?. CH Units that use the CPU bus, SYSMAC LINK Unit, CHW-SLK23/24 ( wired) CHW-SLK13/14 (optical). Controller Link Unit, CHW-CLK21 (wired ).

Author: Juramar Tojalkree
Country: Turks & Caicos Islands
Language: English (Spanish)
Genre: Technology
Published (Last): 6 December 2009
Pages: 389
PDF File Size: 16.48 Mb
ePub File Size: 7.65 Mb
ISBN: 283-8-69337-585-7
Downloads: 33621
Price: Free* [*Free Regsitration Required]
Uploader: Gardabei

You should verify the cable. If it is not blinking then you have a bad connection.

Omron C200h-lk201-v1 Host Link Unit

I have tried with an ch-lkv1 but everything is the same. I just didn’t relate the issue when reading the manual.

Posted 16 Nov edited. Then the PLC cannot connect to Pc. On c200hh CPU, led “run” is green. Try to put il elsewhere. I did an internet search for your PLC. You need to be a member in order to leave a comment. It’s on page 9 in the manual.

Last week, the cpu couldn’t power on, so I have replaced with a new CPU. With the information you have provided, there is no way for us to tell. Maybe the backplane is bad.

Omron C200H-LK201-V1 Industrial Control System

The restriction is strictly mechanical. Posted 14 Nov edited. Remove all the modules from the rack and try the Host Link in another slot. And you put it on the first spot left of the CPU. Create an account or sign in to comment You need to be a member in order to leave a comment Create an account Sign up for a new account in our community.

  BERNARD WERBER THE ANTS PDF

Be careful what you plug into it. Also the command level is set lj201 a custom application for full read and write. If possible, which cable I have to use? No electrical or logical restriction for using these slots with CH-LK For communications with CX Programmer, you should be able to use the same cable that is currently connected to you custom application. What is the part number of your back plane?

Omron Ch-lkv1 Host Link Unit | eBay

Posted 22 Nov It determines if addressing is required in the event of a 2c00h system. Started by sokhanh13 Nov But there’s still no RCV light Please help me! Edited 15 Nov by sokhanh. I will check the cable one more time! Jay and Bob, Thanks for the feedback!

This is a node address. I also tried with this cable LK Coputer One of the other old school guys will have to answer this one. Could anyone help me how to check and slove this problem? If this is a 1 to 1 connection between the PC and the PLC then this is probably correct but not guaranteed. The long port c200u the bottom is for a 3G2A6-LK This means you cannot use the small peripheral port for c200 other than a hand held programmer.

  KRONIKI MARSJANSKIE PDF

After revisiting this I found conflicting information in the manuals. C Series Host C2000h Units. This is common Omron serial settings. The dip witches in the host link are correct but still not connect. Posted 15 Nov edited. Help me with ch-lk Started by sokhanh13 Nov Maybe the PLC power supply is bad.

Omron CCNEU Programming Cable, For Use With CH-LK PLC, 6 ft Buy from Cross

I have checked the cable carefullly, the cable should be ok. Sign In Sign Up.

All the configuration is done with the LK switches. Thank you for your reoly! Sign in Already have l2k01 account? Prev 1 2 Next Page 1 of 2. Register a new account. Neither of them are V1’s. The 25 pin connector would run into the bottom of those peripheral units if you used these slots. Can I move the host link to other slot of BB? This is basically the same as the rack mounted unit you have.